Appendix a gives guidance and background information which will assist the designer and the testing laboratory to select and evaluate specimens that are representative of in use situations. Method for classification of the surface spread of flame of products. The bs 476 part 5 is now obsolete and has been withdrawn although it is still quoted in bs 5422. Fire tests on building materials and structures method of test for fire propagation for products 2. Fire tests on building materials and structurespart 22. Fire resistance test utilising the general principles of. Bs 476 22 fire tests on building materials and structures part 22. Fire tests on building materials and structures part 6. The need for a glossary covering terms used in bs 476 has been established and this will be published separately as a british standard glossary of terms and definitions associated with fire. Lpcb approves smoke extraction ducts to en 66 part 8 or en.
All materials shall be tested in accordance with the relevant sections of bs 476. Bs 4766 fire test to building material standard brief this part of bs 476 specifies a method of test, the result being expressed as a fire propagation index, that provides a comparative measure of the contribution to the growth. Other tests being studied may result in the issue of further parts. The british standard 476 bs476 dictates the appropriate fire tests for these elements of structurematerials and grades the level of fire resistance.
Fire protection has already embarked on this testing programme. Part 6, bs 6575, bs 415, bs 3212 replaces bs 476 5. On july 1, 20, the construction products directive cpr becomes a statutory requirement and bs476 part 24 1987 will be withdrawn and the bs en 12101 series part construction standards will take precedence. Fire tests on building materials and structures bs 476. To facilitate the use of the new european fire test methods.
A thermocouple is inserted into the centre of the specimen and connected to the logging equipment. Flat plate section aa clamping frame in closed position with specimen in. However the british standard 476 dictates the appropriate fire tests for these elements of structurematerials and grades the level of fire resistance. Once you have purchased your british standards download you will be entitled to download one copy of each british standards pdf onto a single computer. Bs 5588 part 6 ebooks pdf free bs 5588 part 6 downloadpdf ebook and manual free download, free pdf ebooks users guide, manuals, sheets about bs 5588 part 6 automatic transmissions and part 23. We manufacture flameshield fireduct from the highest quality, galvanised sheet steel and is produced on specialist manufacturing systems. Method of test to determine the classification of the surface spread of flame of products bs 47611. The tests that are relevant to the solid surface industry are the bs476 part 6, and bs476 part 7. Method for determination of the fire resistance of elements of construction general principles standard. The test produces a fire rating of class 1, 2, 3 or 4 depending upon how far a flame travels over a coated surface. Bs 476 22 has been prepared under the direction of the fire standards committee, and describes the procedures for determining the fire resistance of nonloadbearing elements of building construction. Fire tests on building materials and structures part 7.
An example of a bs standard that cannot be purchased as a downloadable british standard is bs 5252f. This part of bs 476 specifies a method of test for measuring the. Classification and method of test for external fire exposure to roofs. However, the latter will still be made available on request since it is referred to in building regulations and other legislative documents. Fire classification in accordance with british standards. This standard has been superseded by the current bs en 661, bs en 668 and bs en 669, but it has been retained based on a legitimate need for the standards within noneu markets. S to indicate whether the test results apply to a flat horizontal or an inclined roof system, respectively. Flameshield fireduct fire rated ductwork bs 476 part 24. To achieve class 0 a product must achieve class 1 in the part 7 test and also pass the part 6 test. Two doors being testing for 60 and 90 minutes using ramkor core. The sample exposed to high temperature and pressure conditions, the test samples within the specified time bearing weight, integrity and insulation. Product standards flameshield fireduct is fully compliant with bs 476 part 24 flameshield products have been fully tested in accordance with bs 476 part 24. Furnace the furnace was controlled so that its mean temperature complied with the requirements of bs 476.
Main body of apparatus main body of apparatts clamping frame shwn in almst fully open position. A british standard does not purport to include all the necessary provisions of a contract. This part should be read in conjunction with bs 47620 which. General the instrumentation provided was in accordance with bs 476. Part 1, bs 5423, bs 5852, health and safety at work etc. Method for determination of the fire resistance of nonloadbearing elements of construction the sample exposed to high temperature and pressure conditions, the test samples within the specified time bearing weight, integrity and insulation. The following is reproduced from clause 4 of bs 476. The purpose of bs476 part 24 1987 and iso6944 1985 is to. Bs 4764 fire tests on building materials and structures part 4. Bsi bs 4768 fire tests on building materials and structures part. Bs 476 part 20, the objective of determining fire resistance, as described in the part and the associated parts of bs 476, is to assess the behaviour of a specimen of an element of building construction when subjected to defined heating and pressure condi. The purpose of bs476 part 24 and iso6944 is to measure the ability of a.
Tl1010 flammability of materials for vehicle interiors. The test was performed in accordance with the test procedures specified in bs 476. The specimen should be tested at full thickness provided that it can be fitted into the specimen holder, if not, the unexposed face should be cut away to reduce the thickness to a minimum of 50 mm. Fire resisting ductwork tested to bs 476 part 24 blue. Schedule of accreditation united kingdom accreditation service.
This part, together with bs 47620, 21, 23 and 24, supersedes bs 4768. Part 24 fire tests on building materials and structures. Flameshield fireduct, fire rated ductwork, bs 476 part 24. A bs 4767 fire test to building material standard brief this part of bs 476 specifies a method of test for measuring the lateral spread of flame along the surface of a specimen of a product orientated in the vertical position under opposed flow conditions, and a classification system based on the rate and extent of the spread of flame. Fire resisting ductwork tested to bs 476 part 24 blue book. Method of test for fire propagation for products bs 4766. Fire tests on building materials and structures part 11. An example of a downloadable british standard is bs en iso 9001. This standard has been superseded by the current bs en 651, bs en 652, bs en 653 and bs en 654, but it has been retained based on legitimate need for the standards within noneu markets. This document was uploaded by user and they confirmed that they have the permission to. Part 7 the complete assembly of materials as installed shall achieve a class 1 spread of flame. For bench tests, the variations in the burning rate of products are. Scribd is the worlds largest social reading and publishing site. Flat plate section aa clamping frame in closed position with specimen in situ.
Test methods and criteria for the fire resistance of elements of building construction amd 1873 amd 3816 amd 4822 no longer current but cited in building regulations guidance publication year 1972 document status. This method of test, the result being expressed as a fire propagation index, provides a comparative measure of the contribution to the growth of fire made by an essentially flat material. All bsi british standards available online in electronic and print formats. Presentation bs 476 free download as powerpoint presentation. Fire resistance test utilising the general principles of bs. Method for assessing the heat emission from building materials bs 47612.
Flameshield fireduct we manufacture and supply flameshield fireduct bs flameshield fireduct bs was the first noncoated ductwork system to achieve full compliance to all parts of the bs 476 part 24. Method using a choice of seven flaming ignition sources for a variety of flame application times. Amendment c1 dated april 2014 information added to foreword. Fire test on building materials and structurespart 21. This part should be read in conjunction with bs 476 20 which describes the general principles for these methods. Fire tests on building materials and structures part 20. The building regulations stipulates the rules and the degree of fire resistance of the elements of structure. Bs 476 is the british standard produced by bsi group and is the common standard adhered to in the gcc region, united kingdom and europe. Fire resistance test to building material loadbearing. The bsi group produces british standards under the authority of the royal charter in the united kingdom, which states that one of bsis objectives is to create standards of quality for goods and services. The general changes made to the methods described in this part compared with bs 4768 are described in the foreword to bs 47620. Bs 47622 has been prepared under the direction of the fire standards committee, and describes the procedures for determining the fire resistance of nonloadbearing elements of building construction.
1392 895 509 302 946 604 403 1275 947 137 660 1403 948 437 1452 741 1149 969 223 999 1437 898 1043 1382 606 871 484 685 1453 748 1388 691 474 273 1188 21